Nexus 500
5 - Check the control unit connector. Check the
control unit.
6 - Check the continuity between pin 15 of the CPU
and the brown-black wire of the 6 input connector
of the instrument unit.
The injection CPU manages the negative of the light. The light must go off after the initial check. The
light goes on again when the CPU autodiagnosis detects a fault. When the fault disappears the light
goes back off, however, the related operating tests need to be carried out. The light can go on whether
the engine is able to run or not.

Self-diagnosis system

The injection control unit is provided with an auto-diagnosis function.
When a failure is detected, the control unit:
- turns on the injection indicator (only when it is current).
- enables the engine management check according to the data entered in the control unit (where pos-
sible).
- stores the failure (always).
In the event of intermittent failures, the indicator follows the failure trend and storage remains active.
Stored data are automatically deleted when the failure does not occur for over 16 usage cycles of the
scooter (heating - use - cooling). The battery disconnection does not delete stored data.

Checking stored failures

Connect the diagnostic tester to the scooter sys-
tem.
Select the function "ERROR" in the menu.
Specific tooling
020460Y Scooter diagnosis and tester
Injection
INJEC - 27