Table Of Contents - Gilera Nexus 500 Workshop Manual

Hide thumbs Also See for Nexus 500:
Table of Contents

Advertisement

1 - Check whether the immobiliser system LED in-
dicates that the switch is in position "ON" and that
the deterrent flashing is on.
Yes Go To 2 NO go to 7
2 - The decoder is properly programmed.
3 - Switch set to "ON" with side stand raised and
emergency switch set to "OFF". The injection in-
dicator turns on for about 3 seconds.
YES go to 5 NO go to 4
4 - Check the instrument unit and its power supply.
YES go to 3
5 - Set the emergency switch to "RUN". The injec-
tion warning light comes on for about 5 seconds.
6 - The injection controller is certainly powered.
7 - Check the efficiency of the 3 A fuse no. 3 loca-
ted in the fuse-holder under the right side.
YES go to 10 NO go to 8
8 - Fix any wiring short circuits and replace the
fuse.
YES go to 1 NO go to 9
9 - Check any short circuit on decoder or control
unit and replace, if necessary.
YES go to 1
10 - Place the special tool between control unit and
power supply system. Disconnect the main de-
coder connector and check the following condi-
tions:
Terminal no. 3= battery positive
INJEC - 20
Nexus 500