Engine
- Oil pressure sensor feeding duct.
- Oil vapour decantation chamber
- Reinstall the blow-by reed valve using a new
sealing gasket.
- Reinstall the support with head and tighten the
screws to the prescribed torque.
Locking torques (N*m)
Supporting screws with bulkhead 0.3 - 0.4
- Install a new sealing ring for the pump shaft using
the special tool
- Install the oil minimum pressure sensor and tight-
en to the prescribed torque.
Specific tooling
020376Y Adaptor handle
020412Y 15 mm guide
Locking torques (N*m)
Minimum oil pressure sensor 12 ÷ 14