System Board Configuration - Fujitsu SPARC EnterpriseM3000 User Manual

Table of Contents

Advertisement

System Board Configuration (Continued)
TABLE 2-30
Item
Description
Delete device
The device, such as a system board, is deleted.
Replace device The device, such as a system board, is replaced.
Diagnosis
Diagnose the system board.
The specified system board must be unconfigured from the
domain or the domain in which the system board is
configured must be powered off.
Note – (1) Memory mirroring requires twice the amount of memory domain used
for operation. If the PSB is a Quad-XSB type in M8000/M9000 servers, memory
mirroring cannot be used. In M4000/M5000 servers, memory mirroring can be used
regardless of whether the system board is a Uni-XSB or Quad-XSB.
Note – (2) The add/delete/replace operations are done by field engineers (FEs). If a
command is performed, the maintenance guidance is displayed. FEs will use the
device check, select, add, and delete operations in the guidance window. For
information about how to handle and operate these devices, see the Service Manual
for your server and any manual written for FEs.
Dividing a PSB Into XSBs
1. Use the showfru(8) command to display information on dividing a PSB into
XSBs.
XSCF> showfru –a sb
Device
sb
sb
sb
2. Use the setupfru(8) command to divide a PSB into XSBs.
<Example> Specify PSB#00 for a Quad-XSB.
XSCF> setupfru –x 4 sb 00
2-176
SPARC Enterprise Mx000 Servers XSCF User's Guide • January 2012
Command operation
Location
XSB Mode
00
Uni
01
Uni
02
Uni
Shell Command
deletefru
replacefru
testsb
Memory Mirror Mode
No
No
No
Remarks
(Note 2)
(Note 2)