B.4.2
Temperature and Humidity History Log
Using the showlogs(8) Command to Reference Temperature and
Humidity History Logs
The XSCF firmware collects the environment and temperature and humidity history
regarding the server in a temperature and humidity log. The temperature and
humidity history log is displayed at ten-minute intervals. Specify the env option on
the XSCF Shell and perform the showlogs(8) command to reference temperature
and humidity history logs. The following items are displayed:
Time at which each thermal log was collected (Date). This is indicated in local
■
time.
Temperature (Temperature)
■
Humidity (Humidity). The humidity is only displayed in the M8000/M9000
■
servers.
Power supply status (ON or OFF) of the server (Power).
■
B.4.3
Console Log
Using the showlogs(8) Command to Reference Console Logs
The XSCF firmware collects the domain console messages output through the XSCF
in a console log. A console log is collected as one entry for each line feed code. In
some cases, console logs may be called console message logs. Specify the console
option on the XSCF Shell and perform the showlogs(8) command to reference
console logs. The following items are displayed:
Domain ID (DomainID)
■
Time at which each console log was collected (Date). This is indicated in local
■
time.
Console message (Message)
■
Appendix B
XSCF Log Information
B-9