5-7 COMPLETE CONTROL
PANEL - HENNY PENNY

5-8 PRESSURE REGULATION

5-6
Should the Control Panel not operate, replace the panel as follows:
1. Remove electrical power supplied to the fryer.
Place the Power/Pump Switch in the "OFF" position, and
unplug the power cord and/or turn off the wall circuit breaker,
or electrical shock could result.
2. Remove the two screws securing the Control Panel and lift
panel up and out.
3. Unplug the connectors going to the Control Board.
4. Install new Control Panel.
When plugging connectors into new Control Panel, be sure
connectors are lined-up correctly, such as, connector is not
plugged in backwards, or damage to the board could result.
The Henny Penny Fryer uses pressure as one of the components of
the cooking process. Once the lid is sealed to the cookpot, and the
solenoid valve closes, a deadweight valve maintains the correct
pressure in the cookpot.
The lid has minimal and limited maintenance and repair procedures,
which are addressed in the following sections.
The following is a routine maintenance schedule for the Lid:
Every 90 days
• Clean and reverse lid gasket
Yearly Inspection
• Remove and clean safety relief valve
• Check Lid Gasket for splitting and tears - replace if necessary
• Check Pressure Pads for wear - rotate if necessary
• Check Cam Slide Guides - replace if worn or broken
• Check Lid Rollers - replace if cracked or damaged.