3-3. MELT CYCLE OPERATION

3-4. SWITCHES AND
INDICATORS
"Lo" Mode
"Cool" Mode
501
If the shortening is below 185
Pump Switch in the "Power" position, the fryer enters the melt
cycle. The shortening is heate slowly to prevent scorching of
the shortening. The display reads "LO" and the heat cycles, 10
seconde on, 30 seconds off, to ensure slow melting of shorten-
ing. No othe rbutton on the control panel operates except the
Power/Pump Switch.
NOTE
Should you require outside assistance, just call 1-800-417-
8405, or 937-456-8405.
If the fryer has the FAST controls, see the FAST
operation manual.
The display will read "LO" anytime the shortening temperature
is below 250° F. When the Power/Pump Switch is placed in
the "Power" position, the control will begin a melt mode which
cycles the heat on and off. This slowly melts/heats the shorten-
ing until the temperature reaches 185° F (85° C). This heat
stays on until the "COOL" mode is reached, or until reaching
the temperature of the selected cooking cycle.
After cooking or filtering the shortening, the temperature will
automatically go into the "COOL" mode which keeps shorten-
ing at 250° F (121° C). This temperature extends the shorten-
ing life and minimizes the time needed to heat the shortening for
the next cook cycle. Press "Exit Cool" to leave the "Cool"
mode, then press product button for the cook cycle desired.
To manually place the controls in the "COOL" mode, start a
cooking cycle, and then press the cycle button again. The
display should then show "COOL. See Cycle Selection below.
Although the display will read "COOL" in the standby
mode, the shortening is hot and could cause burns.