Henny Penny 680 KFC Service Manual page 37

Pressure fryer
Table of Contents

Advertisement

DONOTOPERATE
UNIT IF HIGH
PRESSURE CONDI-
TIONS EXIST.
SEVERE INJURIES
AND BURNS WILL
RESULT. Place the
Power/Pump switch in
the "OFF"
position
immediately. Release the
pressure by allowing
unit to cool. The pressure
will then drop. Do not
resume use of unit until
cause of high pressure
has been found and
corrected.
Pressure does not
build
Exhaust line to stack
clogged.
Not enough product in fryer
or product not fresh.
eta1 shipping spacer not
removed from dead weight.
Lid open or not latched.
Solenoid valve leaking or
not closing.
Dead weight valve leaking.
Pressure not programmed.
Lid gasket leaking.
Safety relief valve leaking.
Pressure plate broken or
crushed.
Clean exhaust line to stack.
Place proper quantity of
fresh product within
cookpot to generate steam.
* Remove shipping spacer.
See Unpacking Section.
Close and latch lid.
Check or clean solenoid
valve per maintenance
section on the solenoid
valve.
Repair per maintenance sec-
tion on operating valve.
Check programming.
Shims need to be placed
under pressure pads. See
maintenance section under
lid system.
Check and replace if
necessary per maintenance
section on the relief valve.
eplace pressure plate.