Shortening will
not heat. "E20"
Blown fuse or tripped
circuit breaker at supply
box or control panel.
lown fuse in PC board.
Faulty Power/Pump switch.
Faulty cord and plug.
Check power at receptacle.
Faulty drain switch.
Faulty PC Board.
Faulty high limit control
switch.
Drain valve open.
ossible faulty gas control
valve.
ossible faulty probe
itor.
Low air pressure into
burner chamber.
Faulty ignitor module.
Reset breaker or replace
fuse.
Replace glass fuse in board.
Check Power/Pump switch
per maintenance section on
the power/pump switch.
Check cord and plug and
power at wall receptacle.
Check drain switch per
maintenance section on
drain switches.
Remove and replace control
panel.
Check high limit control
switch per maintenance
section on the high limit.
Close drain valve.
With power removed from
fryer, check across elec-
trical leads of gas valve
with multimeter, and gas
valve on "ON" position.
Replace probe.
Replace ignitor.
Clean or replace blower.
Replace air pressure switch.
Replace module.