2-6. TEMPERATURE PROBE
REPLACEMENT (Continued)
Figure 2-2
2-7. COMPLETE CONTROL
PANEL-HENNY PENNY
806
7. Tighten hand tight and then a half turn with wrench.
Excess force will damage temperature probe.
8. Connect new temperature probe to PC board and replace
control panel.
9. Replace shortening.
10. Turn power on and check out fryer.
Should the control panel become inoperative, follow these
instructions for replacing the board.
1. Remove electrical power supplied to the fryer.
To avoid electrical shock or property damage, move the
POWER switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
2. Remove the two screws securing he control panel and lift
panel up and out
3. Unplug the connectors going to the control board.
4. Install a new control panel.
Model OFG- 390
2-6