Henny Penny 680 KFC Service Manual page 77

Pressure fryer
Table of Contents

Advertisement

Product One
Pressure Solenoid
and Neat Control
Select Time
Product Indicators
Select Function
Function Indicators
Change Button
Change Button
Under Display 4
Indicator Display
Change Button
Change Button
Under Display 3
Indicator Display
Change Button
Change Button
Under Display 2
Indicator Display
Change Button
Change Button
Under Display 1
Indicator Display
The SELECT FUNCTION or SELECT TIME button
must be depressed before the PRODUCT ONE button
to properly perform the solenoid and heat control
output test.
For short durati
perate without
temperature
regulation,
or will
overheat
the
shortening.
When programming one-step KFC parameters, load compen-
sation and proportional control are automatically programmed
into the control. The following defines these two functions.
- Load compensation adjusts cooking
sate for differences in the cooking process such
as load size. The control is continuously comparing the pot
temperature
to the setpoint
temperature.
If the pot
temperature is above the setpoint, the control will shorten the
cook time. If the pot temperature is below the setpoint, the
control will lengthen the cook time. Load compensation for
KFC parameters is set at 0.
= Proportional control regulates pot
the heat on and off until it reaches
setpoint temperature. This allows better temperature accuracy
when dropping
product.
Proportional
control for KFC
parameters is set at 10 degrees.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents

Save PDF