5-12. COMPLETE CONTROL
PANEL HENNY PENNY

5-13. PRESSURE REGULATION

5-12
Should the Control Panel become inoperative, follow these
instructions for replacing the board.
1. Remove electrical power supplied to the fryer.
Place the Power/Pump Switch in the "OFF" position,
and unplug the power cord and/ or turn the wall circuit
breaker off or electrical shock could result.
2. Remove the two screws securing the Control Panel and
lift panel up and out.
3. Unplug the connectors going to the Control Board.
4. Install a new Control Panel.
When plugging connectors into new Control Panel be
sure connectors are put on in the correct manner, such
as, be sure connector isn't put on backwards.
The Henny Penny Fryer uses pressure as one of the
components of the cooking process. Once the lid is
sealed to the cookpot, and the solenoid valve closes, a
deadweight valve maintains the correct pressure in the
cookpot.
The lid has minimal and limited maintenance and
repair procedures, which are addressed in the
following sections.
Model 580