2-8. COMPLETE CONTROL
PANEL-HENNY PENNY

2-9. PRESSURE REGULATION

1103
Should the control panel become inoperative, follow these
instructions for replacing the board.
1. Remove electrical power supplied to the fryer.
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
2. Remove the two screws securing he control panel and lift
panel up and out
3. Unplug the connectors going to the control board.
4. Install a new control panel.
The Henny Penny Fryer uses pressure as one of the compo-
nents of the cooking process. Once the lid is sealed to the
frypot, and the solenoid valve closes, a deadweight valve main-
tains the correct pressure in the frypot.
The lid has minimal and limited maintenance and repair proce-
dures, which are addressed in the following sections.
The following is a routine maintenance schedule for the Lid:
Every 90 days
Clean and reverse the lid gasket
Yearly Inspection
Check Lid Gasket for splits and tears-replace if necessary
Check Pressure Pads for wear-rotate if necessary
Check Cam Slide Guides-replace if worn or broken
Check Lid Rollers-replace if cracked or damaged
Model 590/592