Chapter 3 Rack Installation
3.2 Installing Controller Enclosure
(2)
Insert the pins of the left slide rail in the 1st and 3rd holes from the bottom of the 2U Bracket.
(3)
Secure the left slide rail to the front pillar using the M5 centering screw and M5 pan head screw.
(4)
For the right slide rail, insert the pins in the holes of the rear pillar, and secure the other side of the
slide rail to the front pillar in the same way as the left slide rail.
(5)
Push the M5 cage nuts into the 2nd holes of the front rack pillars above the base line of the
controller enclosure.
The M5 centering screw and M5 pan head screw positions for the slide rails and 2U Bracket are
determined relatively to the base line of the controller enclosure.
Tighten the screws referring to the following figure.
(M5 centering screw)
(M5 pan head screw)
ETERNUS DX80 S2/DX90 S2 Disk storage system User's Guide -Installation-
[Left]
3rd position
2nd position
2U
Controller enclosure
(M5 cage nut)
1st position
Base line of
controller enclosure
Copyright 2013 FUJITSU LIMITED
M5 cage nut
M5 pan head screw (10mm)
[Right]
3rd position
(M5 centering screw)
2nd position
(M5 cage nut)
1st position
(M5 pan head screw)
Rack rails
53
M5 centering screw (10mm)
P3AM-4832-07ENZ0