Chapter 5 Setup
5.1 Basic Setup
2
After about two minutes, check that the READY LED of the controller enclosure is lit up.
When checking the connection between the PC terminal and the ETERNUS DX Disk storage system,
execute the "ping" command at the PC command prompt. An example of ping execution is shown
below: ("192.168.1.1" is the default IP address)
ping 192.168.1.1
If the execution results in an error, check the network settings of the PC terminal.
If communication fails even though the MNT port of Controller 0 (CM#0) and the LAN port of the PC
terminal are connected, check that the Master LED of Controller 0 (CM#0) is on. If the Master LED of
Controller 1 (CM#1) is on for a dual-controller type, use the MNT port of Controller 1 (CM#1).
5.1.3

ETERNUS Web GUI Startup

Start up ETERNUS Web GUI in the Web browser of the connected PC terminal.
Procedure
1
Open the Web browser on the PC terminal.
2
Enter either of the following URLs in the address bar of the Web browser.
http://192.168.1.1/
The login screen for ETERNUS Web GUI appears.
3
To change the user interface language, click the [Option] button and select "English" or
"Japanese" in "Language".
ETERNUS DX80 S2/DX90 S2 Disk storage system User's Guide -Installation-
LINE
FAULT
POWER
POWER
READY
FAULT
MAINT/ID
CACHE
Copyright 2013 FUJITSU LIMITED
Drive enclosure
Drive enclosure
Controller enclosure
91
End of procedure
P3AM-4832-07ENZ0