Window Comparator (Wcfv/Wcfi) (Disconnection Detection Fvdc/Fidc); Frequency Reference Selection Status Signal (Fref); Run Command Status Signal (Ref) - Omron MX2 Series User Manual

Mx2 series type v1 multi-function compact inverter
Hide thumbs Also See for MX2 Series:
Table of Contents

Advertisement

FV/FI input
Max. (100%)
Min. (FV/FI: 0%)
WCFV/WCFI output
FVDc/FIDc output
Additional Information
To use this function for disconnection detection, set the disconnection detection level in the
Window Comparator FV/FI Upper Limit Level (b060/b063).
(In this case, the inverter uses the bandwidth over the upper limit value in normal operation
and, if the input falls below the upper limit value, the inverter detects a disconnection error.)

7-8-21 Frequency Reference Selection Status Signal (FREF)

This signal will be output when the RUN command is input via the Digital Operator (A001=02), or when
the forced operator function (31: OPE) is allocated to one of the multi-function output terminals and that
terminal is ON.
It is OFF when the RUN command is not input via the Digital Operator.
Parameter
No.
C021, C022
Multi-function Output P1/P2 Selection 58:
Multi-function Relay Output (MA, MB)
C026
Function Selection

7-8-22 RUN Command Status Signal (REF)

This signal will be output when the RUN command is input via the Digital Operator (A001=02), or when
the forced operator function (31: OPE) is allocated to one of the multi-function output terminals and that
terminal is ON.
It is OFF when the RUN command is not input via the Digital Operator.
Parameter
No.
C021, C022
Multi-function Output P1/P2 Selection 59:
Multi-function Relay Output (MA, MB)
C026
Function Selection
Multi-function Compact Inverter 3G3MX2-V1 User's Manual (I585-E1)
Hysteresis width
(b062, b065)
Analog operation level
Analog input value
Function name
Function name
7 Other Functions
Window comparator
upper limit level
(b060/b063)
Analog operation level at disconnection
( b070/b071 )
Window comparator
lower limit level
(b061/b064)
Data
FREF (Frequency com-
mand source)
Data
REF (RUN command
source)
7
Default
Unit
data
Default
Unit
data
7 - 89

Hide quick links: