Returning Display To D - Omron MX2 Series User Manual

Mx2 series type v1 multi-function compact inverter
Hide thumbs Also See for MX2 Series:
Table of Contents

Advertisement

Returning Display to d001

Regardless of the display mode of the Digital Operator, if you press
more, the data of Output Frequency Monitor (d001) is displayed. However, the Digital Operator contin-
ues to display the function mode and extended function mode in sequence as the normal operation if
you press the Mode key for less than 3 seconds.
Changes in Operation Method from Previous Models (3G3JX Series etc.)
For the 3G3MX2 Series, the operation method was changed from the previous models (3G3JX Series
etc.).
The 3G3MX2-V1 Series uses the same operation method as that of the previous 3G3MX2 Series.
Below are the differences of this inverter in the operation method from the previous models (3G3JX
Series etc).
The optional Digital Operator (Model: 3G3AX-OP01) also uses the same operation method as the Digi-
tal Operator built into this inverter.
Elimination of the top display layer (Overall display of each parameter group)
The top display layer
ter groups remains as before.
Change of scroll behavior in each parameter group
The parameter numbers loop in each parameter group when scrolled.
In the previous model, when the highest parameter number in a group appears, the display switches
to display the first parameter number in the next group.
Functions of Mode key and Enter key
The functions of the Mode key and Enter key were changed as follows for consistency and simplicity
in operation.
Name
Enter key
Mode key
Multi-function Compact Inverter 3G3MX2-V1 User's Manual (I585-E1)
in the operation was eliminated, although the concept of the parame-
Previous model: 3G3JX Series etc.
• Moves to the upper layer.
• Enters or stores the value and returns to
the parameter display.
• Moves to the upper layer.
• Moves to the parameter display.
• Moves to the data display.
• Cancels the setting and returns to the
parameter display.
• Displays the data of Output Frequency
Monitor (d001) if you press the Mode key
for 3 seconds or more.
3 Operation and Test Run
(Mode key) for 3 seconds or
This model: 3G3MX2 Series
(both the previous 3G3MX2 and Type V1)
• Moves to the data display.
• Enters and stores the setting and returns
to the parameter display.
• Moves to the beginning of the next param-
eter group.
• Cancels the setting and returns to the
parameter display.
• Displays the data of Output Frequency
Monitor (d001) if you press the Mode key
for 3 seconds or more.
3
3 - 11