Modbus
Register
register
No.
spec. No
1F33 hex
1F32 hex 1st Deceleration Time 1
1F34 hex
1F33 hex
1F35 hex
1F34 hex
1F36 hex
1F35 hex
1F37 hex
1F36 hex
1F38 hex
1F37 hex 1st Frequency Upper Limit
1F39 hex
1F38 hex 1st Frequency Lower Limit
1F3A hex
1F39 hex
1F3B hex
1F3A hex
1F3C hex
1F3B hex
1F3D hex 1F3C hex
1F3E hex
1F3D hex
Inverter control input register No. 1F01 hex
Bit
15
Name
Opr
RUN command (0: Stop/ 1: RUN)
Dir
Rotation direction command (0: Forward/1: Reverse)
EXT
External trip
RS
Reset
In1
Multi-function Input S1
In2
Multi-function Input S2
Inverter status monitor register No. 1E01 hex
Bit
15
Name
ONT
Dir
Rotation direction (0: Forward/1: Reverse)
IRDY
Inverter ready
RUN
During RUN
FA1
Constant speed reached
FA2
Set frequency exceeded
OL
Overload warning
OD
Excessive PID deviation
Multi-function Compact Inverter 3G3MX2-V1 User's Manual (I585-E1)
Function name
1st Multi-step Speed
Reference 0
Multi-step Speed
Reference 1
Multi-step Speed
Reference 2
Multi-step Speed
Reference 3
Acceleration Stop Fre-
quency
Frequency Addition
Amount Setting
Deceleration Stop Fre-
quency
PID Sleep Operation
Level
Frequency Matching
Lower Limit Frequency
14
13
12
11
10
In7
In6
In5
In4
14
13
12
11
10
RNT
TRQ
UV
OTQ
8 Communications Functions
Parameter
R/W
Monitor or setting data
No.
F003
R/W
0 to 65535
0/Starting Frequency to 1st
A020
R/W
Maximum Frequency
0/Starting frequency to
A021
R/W
Maximum frequency
0/Starting frequency to
A022
R/W
Maximum frequency
0/Starting frequency to
A023
R/W
Maximum frequency
0/Frequency Lower Limit to
A061
R/W
Maximum Frequency
A062
R/W
0 to Frequency Upper Limit
0.00 to Starting Frequency:
Disabled
A069
R/W
Frequency above Starting
Frequency to 40000
A145
R/W
0 to 40000
0.00 to Starting Frequency:
Disabled
A154
R/W
Frequency above Starting
Frequency to 40000
A156
R/W
0 to 40000
b007
R/W
0 to 40000
9
8
7
6
5
In3
In2
In1
In3
In4
In5
In6
In7
9
8
7
6
5
FA3
AL
OD
OL
FA2
AL
Alarm
FA3
Set-frequency only
OTQ
Overtorque/Undertorque
UV
Undervoltage
TRQ
Torque limit
RNT
RUN time over
ONT
Power ON time over
Data
resolu-
tion
0.01 [s]
0.01
[Hz]
0.01
[Hz]
0.01
[Hz]
0.01
[Hz]
0.01
[Hz]
0.01
[Hz]
0.01
[Hz]
0.01
[Hz]
0.01
[Hz]
0.01
[Hz]
0.01
[Hz]
4
3
2
1
0
RS
EXT
Dir
Opr
Multi-function input S3
Multi-function input S4
Multi-function input S5
Multi-function input S6
Multi-function Input S7
4
3
2
1
0
FA1
RUN
IRDY
Dir
8 - 27
8