Sign In
Upload
Manuals
Brands
Omron Manuals
Inverter
3G3MX2-A4030-V1
Omron 3G3MX2-A4030-V1 Manuals
Manuals and User Guides for Omron 3G3MX2-A4030-V1. We have
2
Omron 3G3MX2-A4030-V1 manuals available for free PDF download: User Manual, Instruction Manual
Omron 3G3MX2-A4030-V1 User Manual (620 pages)
MX2 Series Type V1 Multi-function Compact Inverter
Brand:
Omron
| Category:
Inverter
| Size: 31.49 MB
Table of Contents
Introduction
3
Intended Readers
3
Manual Configuration
4
Manual Structure
5
Special Information
6
Sections in this Manual
7
Terms and Conditions Agreement
8
Safety Precautions
10
Explanation of Symbols
11
Precautions for Safe Use
14
Operation and Adjustment
14
Maintenance and Inspection
15
Precautions for Correct Use
16
Motor Overload Protection
16
Warning Label
17
Regulations and Standards
18
Ec Directives and Ul/Cul Standards
18
Trademarks
19
Items to Check after Unpacking
20
Checking the Nameplate
20
Checking the Accessories
21
Related Manuals
22
Revision History
23
Table of Contents
24
Contents
25
Overview
33
Section 1 Overview
34
Overview of Functions
34
Features of 3G3MX2-V1 Series Inverter
34
Simple Position Control
35
Sensorless Vector Control
35
Compliance with Safety Standards
36
Ease of Use
37
Classes of 3G3MX2-V1 Series Inverter
38
Compliance with International Standards (EC Directives and Ul/Cul Standards)
39
Compliance with International Standards
39
Appearance and Part Names
40
Specifications
44
Standard Specifications
44
Common Specifications
47
External Dimensions
49
Restrictions
55
Comparison with Previous Model
57
Modbus Mapping Function
58
Design
61
Section 2 Design
64
Installation
64
Inverter Installation
64
Installation Environment
64
Installation Conditions
65
Removal of each Part
67
Removing Covers
67
Terminal Blocks
68
Preparing Backing Plate
69
Wiring
70
Standard Connection Diagram
70
Arrangement and Function of Main Circuit Terminal Block
71
Arrangement and Function of Control Circuit Terminal Block
72
Wiring for Main Circuit Terminals
75
Before Wiring
86
Wiring Method
87
Wiring for Control Circuit Terminals
93
Wiring for RS485 Communications Terminals
100
Wiring for Digital Operator
102
Safety Function (under Application for Standards)
103
Compliance with EC Directives
104
Section 3 Operation and Test Run
112
Operation of Digital Operator
112
Part Names and Descriptions
112
Key Operation Method
114
Transition of Parameter Display
115
Parameter Initialization
117
Returning Display to D
119
Connections and Functions of CX-Drive
121
CX-Drive Connection Method
121
Overview of CX-Drive Functions
125
Flow of Test Run
129
Operation Items for Test Run
130
Parameter Setting
132
No-Load Run
133
Stopping Motor
133
Load Run
134
Parameter List
135
Section 4 Parameter List
136
Monitor Mode
136
Group D
136
Function Mode
139
Group F: Basic Function Parameters
139
Extended Function Mode
140
Group A: Standard Function Parameters
141
Group B: Detailed Function Parameters
148
Group C: Multi-Function Terminal Function Parameters
158
Group H: Motor Control Parameters
166
Group P: Option/Applied Function Parameters
169
Group U: User Parameters
175
Basic Settings
177
Section 5 Basic Settings
179
Parameter Display and Parameter Initialization
179
Display Selection
179
Parameter Initialization
182
V/F Control Settings
185
Control Method (V/F Characteristics)
185
Heavy Load/Light Load Selection
188
Motor Parameter Settings
192
Motor Capacity/Pole Number Selection
192
Electronic Thermal Function
192
Additional Information
193
Electronic Thermal Characteristics
194
Reduced Torque Characteristics
194
Constant Torque Characteristics
195
Base Frequency and Maximum Frequency of Motor
197
RUN Command Settings
198
RUN Command Selection
198
Frequency Reference Settings
200
Frequency Reference Selection
200
Frequency Reference Correlation Chart
206
Frequency Limit
207
Acceleration/Deceleration Time Settings
209
Acceleration/Deceleration Pattern
210
2-Step Acceleration/Deceleration Function
213
Stop Method Settings
215
Stop Selection
215
Free-Run Stop Selection
215
STOP Key Selection
218
Reset Method Settings
219
Reset
219
Restart after Resetting
221
Multi-Function Input Settings
223
Multi-Function Input Selection
223
Multi-Function Input Operation Selection
224
Input Terminal Response Time
224
Forward RUN Command (FW) and Reverse RUN Command (RV)
224
Multi-Step Speed Operation Function
225
Jogging (JG)
228
2-Step Acceleration/Deceleration (2CH)
229
Reset (RS)
229
3-Wire Input Function (STA, STP, F/R)
230
Multi-Function Output Settings
231
Multi-Function Output Selection
231
Multi-Function Output Operation Selection
231
Multi-Function Output ON/OFF Delay Time
232
Signal During RUN (RUN)
232
Constant Speed Arrival Signal (FA1)
233
Alarm Signal (AL)
233
0-Hz Detection Signal (ZS)
234
Operation Ready (IRDY)
235
Forward Run Signal (FWR)
235
Reverse Run Signal (RVR)
235
Torque Boost Function Settings
236
Torque Boost
236
Automatic Torque Boost
237
Manual Torque Boost
238
Measures against Overvoltage
239
Overvoltage Suppression Function During Deceleration
239
Regenerative Braking Function
241
Vector Control and Applied Functions
243
Section 6 Vector Control and Applied Functions
245
Sensorless Vector Control
245
Sensorless Vector Control Parameter Settings
245
Offline Auto-Tuning for Motor Parameters
246
Motor Parameter Settings
251
Adjustments for Sensorless Vector Control
252
Reverse Rotation Prevention Function
253
Torque Limit Function
254
Torque Limit Function Settings
254
Torque LADSTOP Function Settings
256
Overtorque/Undertorque Function
257
Overtorque/Undertorque Function Settings
257
Torque Control
258
Torque Control Settings
258
Torque Bias Function Settings
259
V/F Control with Speed Feedback
260
Settings of V/F Control with Speed Feedback
260
Recommended Encoder and Its Wiring
261
Protective Detection under V/F Control with Speed Feedback
265
Adjustments for V/F Control with Speed Feedback
266
Brake Control Function
267
Operation Sequence of Brake Control Function
267
Brake Control Function Settings
268
Simple Position Control
270
Feedback Settings for Simple Position Control
270
Recommended Encoder for Simple Position Control and Its Wiring
271
Simple Position Control Operation and Settings
276
Origin Search Function, Current Position Preset, Position Data Storage at Power Shutoff
282
Position Data Storage at Power Shutoff
286
Restarting Positioning
287
Multi-Step Position Control Settings
287
Position Command Selection 1 to
288
Turntable Control
289
Speed/Position Switching
290
Interlock Function with Simple Position Control and Brake Control
291
PM Motor Mode
295
PM Motor and PM Motor Control
295
Functional Limitations in PM Motor Mode
297
Switching to PM Motor Mode
299
Offline Auto-Tuning for PM Motor Parameters
299
PM Motor Parameter Settings
303
Adjustment of PM Motor Mode Settings
305
Other Functions
311
Section 7 Other Functions
314
Monitor Mode
314
Output Frequency Monitor [D001]
314
Output Current Monitor [D002]
314
RUN Direction Monitor [D003]
315
PID Feedback Value Monitor [D004]
315
Multi-Function Input Monitor [D005]
315
Multi-Function Output Monitor [D006]
316
Output Frequency Monitor (after Conversion) [D007]
316
Real Frequency Monitor [D008]
317
Torque Reference Monitor [D009]
317
Torque Bias Monitor [D010]
318
Output Torque Monitor [D012]
318
Output Voltage Monitor [D013]
318
Input Power Monitor [D014]
319
Integrated Power Monitor [D015]
319
Total RUN Time Monitor [D016]
320
Total Power on Time Monitor [D017]
320
Fin Temperature Monitor [D018]
320
Life Assessment Monitor [D022]
321
Program Counter (Driveprogramming) [D023]
321
User Monitor 0 to 2 (Driveprogramming) [D025 to D027]
321
Position Command Monitor [D029]
322
Current Position Monitor [D030]
322
Dual User Monitor [D050]
323
Inverter Mode Monitor [D060]
323
Frequency Reference Source Monitor [D062]
324
Run Command Source Monitor [D063]
324
Fault Counter [D080]
324
Fault Monitor 1 to 6 [D081 to 086]
325
Warning Monitor [D090]
325
DC Voltage Monitor [D102]
325
Regenerative Braking Load Rate Monitor [D103]
326
Electronic Thermal Load Rate Monitor [D104]
326
Analog Voltage Input FV Monitor [D130]
326
Analog Current Input FI Monitor [D131]
326
Pulse Train Input RP Monitor [D133]
327
PID Deviation [D153]
327
PID Output Monitor [D155]
327
Multi-Function Input/Output Functions
328
Multi-Function Input Selection
328
Other Functions
329
Multi-Function Output Selection
330
Analog I/O Settings
332
Analog Input (FV, FI)
332
Analog Input Filter
334
Analog Command Hold Function (AHD)
334
Analog Input Adjustment
335
Analog Input Start/End Function Settings
335
Terminal MP (Pulse/Pwm Output)
337
Terminal am (Analog Output)
339
Inverter Control Settings
341
Carrier Frequency
341
Automatic Carrier Reduction
342
2Nd Control Function (SET)
343
Other Operation Functions
345
Starting Frequency
345
Reduced Voltage Startup Selection
346
Frequency Jump Function
346
Acceleration/Deceleration Stop Function
347
RUN Direction Limit Selection
348
Permission of RUN Command
348
Frequency Calculation Function
349
Frequency Addition Function
349
Remote Operation Function (UP/DWN)
350
Output Voltage Gain
351
AVR (Automatic Voltage Regulator) Function
352
PID Function
354
Feedback Selection
357
Automatic Energy-Saving Operation Function
360
Commercial Switching (CS)
360
Stabilization Parameter
362
Pulse Train Frequency Input
362
LAD Cancel Function
363
Digital Operator and Operation Functions
364
Soft Lock Function (SFT)
364
Forced Operator Function (OPE)
365
Forced Terminal Block Function (F-TM)
365
Operation Selection at External Operator Disconnection
366
Initial Screen Selection (Initial Screen after Power-On)
366
Initial Screen Automatic Return Function
366
Inverter Display on Operator Connection
367
Display Fixed (DISP)
367
Password Function
367
Password Setting
368
User Parameter Setting Function
370
User Parameter Automatic Setting Function
370
Restart Functions
371
Frequency Matching Restart and Frequency Pull-In Restart
371
Frequency Pull-In Restart
372
Restart During Power Interruption, Undervoltage/Overvoltage, Overcurrent
373
Power Recovery Restart Prevention Function (USP)
377
Deceleration Stop on Power Interruption Function
378
Functions Related to Protection, Warning, and Various Output Signals
382
Free-Electronic Thermal Function
382
Motor Electronic Thermal Function
383
Electronic Thermal Warning
385
Overload Limit/Overload Warning
386
Overload Warning
388
Overcurrent Suppression Function
389
External Trip (EXT)
389
Thermistor Trip Function
390
Signal During RUN (RUN)
390
Frequency Arrival Signal (FA2 to FA5)
391
RUN Time/Power on Time over (RNT/ONT)
392
Logic Operation Output Signal (LOG1 to LOG3)
393
Capacitor Life Warning Signal (WAC)
394
Cooling Fan Operation
394
Cooling Fan Life Warning Signal (WAF)
395
Communication Disconnection Detection Signal (Ndc)
395
Starting Contact Signal (FR)
396
Cooling Fin Overheat Warning (OHF)
396
Low Current Signal (LOC)
397
Fatal Fault Signal (MJA)
397
Window Comparator (WCFV/WCFI) (Disconnection Detection Fvdc/Fidc)
399
Frequency Reference Selection Status Signal (FREF)
399
RUN Command Status Signal (REF)
399
2Nd Control Selection Signal (SETM)
400
DC Injection Braking Function
401
DC Injection Braking (DB)
401
Safety Function (under Application for Standards)
407
Overview of Safety Function
407
Safety Function Settings
407
Wiring Safety Function for Use
408
Wiring Example
409
Option/Applied Functions (Group P)
411
Operation Selection on Option Error
411
Communications Option Function
411
Driveprogramming Function Parameters
412
Communications Functions
413
Section 8 Communications Functions
415
Communications Specifications
415
RS485 Terminal Arrangement and Connection
416
Modbus Communication Parameters
417
Communications Functions
418
Modbus Communication Protocol
419
Message Configuration
419
Slave Address
420
Required Communications Time
421
Normal Response
421
Abnormal Response
421
No Response
422
Explanation of each Function Code
423
Read Coil Status [01 Hex]
423
Read from Holding Register [03 Hex]
424
Write to Coil [05 Hex]
425
Write to Holding Register [06 Hex]
426
Loop-Back Test [08 Hex]
427
Write to Multiple Coils [0F Hex]
428
Write to Multiple Holding Registers [10 Hex]
430
Read/Write From/To Multiple Holding Registers [17H]
431
Exception Response
432
Saving a Change to Holding Register (Enter Command)
433
How to Issue Enter Command
433
EEPROM Write Mode
435
Modbus Mapping Function
436
Operation of Modbus Mapping Function
436
Modbus Mapping Function Settings
437
Compressed Single-Word Registers
438
Troubleshooting for Modbus Mapping Function
440
Endian Function
441
Co-Inverter Communication
443
Co-Inverter Communication Parameters
444
Co-Inverter Communication Settings
447
Modbus Communication Data Lists
449
Coil Number List
449
Monitor Function/Enter Command Register List
453
Group F Register List
462
Group A/B/C/H/P Register List
463
2Nd Control Register Number List
508
Overview of Driveprogramming
513
Troubleshooting
517
Alarm Display and Remedies
518
Alarm Display
518
Alarm Code List
520
Option Unit Protective Function List
526
Warning Display
528
Other Indications on Digital Operator
529
Troubleshooting
530
Maintenance and Inspection
539
Daily Inspection
541
Cleaning
541
Periodic Inspection
541
Daily/Periodic Inspection Items
542
Megger Test
545
Withstand Voltage Test
545
Inverter/Converter Unit Test
545
I/O Voltage/Current/Electric Power Measurement Method
547
Section 12 Options
551
Overview of Optional Equipment
551
Part Names and Descriptions
551
Regenerative Braking Unit (Model: 3G3AX-RBU )
553
Specifications
553
External Dimensions
555
Connection Examples
559
Braking Resistor (Model: 3G3AX-RBA/RBB/RBC )
560
Specifications
560
External Dimensions
561
Connection Examples
563
Regenerative Braking Unit and Braking Resistor Combination Selection Table
564
DC Reactor (Model: 3G3AX-DL )
568
Specifications
568
External Dimensions
570
Connection Examples
572
AC Reactor (Model: 3G3AX-AL )
573
Specifications
573
External Dimensions
574
Connection Examples
575
Input Noise Filter (Model: 3G3AX-NFI )
576
Specifications
576
External Dimensions
577
Connection Examples
581
Output Noise Filter (Model: 3G3AX-NFO )
582
Specifications
582
External Dimensions
583
Connection Examples
584
Radio Noise Filter (Model: 3G3AX-ZCL )
585
Specifications
585
External Dimensions
586
Connection Examples
586
12-10EMC Noise Filter
587
Specifications
587
Connection Examples
588
12-11Digital Operator (Model: 3G3AX-OP01)
589
Specifications
589
External Dimensions
590
12-12Digital Operator Cable (Model: 3G3AX-OPCN )
591
Specifications
591
External Dimensions
591
12-13Ethercat Communications Unit (Model: 3G3AX-MX2-ECT)
592
Specifications
592
External Dimensions
593
12-14Componet Communications Unit (Model: 3G3AX-MX2-CRT-E)
594
Specifications
594
External Dimensions
595
12-15Devicenet Communications Unit (Model: 3G3AX-MX2-DRT-E)
596
Specifications
596
External Dimensions
597
Appendices
599
Derating
600
Smoothing Capacitor Life Curve
606
Life Alarm Output
607
Ul/Cul Standards Cautions
608
Overview of Inverter Selection
610
Index
615
Advertisement
Omron 3G3MX2-A4030-V1 Instruction Manual (4 pages)
3G3MX2-A*-V1 Multi-function Compact Inverter
Brand:
Omron
| Category:
Inverter
| Size: 0.55 MB
Advertisement
Related Products
Omron SYSDRIVE 3G3MX2-A4030
Omron 3G3MX2-A4037-V1
Omron 3G3MX2-A4030-EV2
Omron 3G3MX2-A4004-V1
Omron 3G3MX2-A4007-V1
Omron 3G3MX2-A4040-V1
Omron SYSDRIVE 3G3MX2-A4015
Omron SYSDRIVE 3G3MX2-A4040
Omron SYSDRIVE 3G3MX2-A4075
Omron 3G3MX2-A4007-EV2
Omron Categories
Blood Pressure Monitor
Controller
Accessories
Switch
Inverter
More Omron Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL