7 Other Functions
The timing in which the inverter releases DC injection braking depends on the value set in the DC Injec-
tion Braking Edge/Level Selection (A056).
(a) Edge operation (A056 = 00)
ON
FW input
A052
Frequency
reference
Output
frequency
7 - 96
FW input
Frequency
reference
Output
frequency
A053
Multi-function Compact Inverter 3G3MX2-V1 User's Manual (I585-E1)
(b) Level operation (A056 = 01)
ON
A052