Omron MX2 Series User Manual page 214

Mx2 series type v1 multi-function compact inverter
Hide thumbs Also See for MX2 Series:
Table of Contents

Advertisement

5 Basic Settings
(Example 1) When 1st/2nd 2-step Accelera-
tion/Deceleration Selection (A094/A294) is set to
00 Switch via 2CH terminal
FW
2CH
Output frequency
Accelera-
tion Time 1
F002/F202 A092/
(Example 3) When 1st/2nd 2-step Acceleration/Decel-
eration Selection (A094/A294) is set to 02 Switch only
during forward/reverse switching
FW
RV
Output
frequency
Acceleration
Time 1
F002/F202
5 - 38
Acceler-
Decelera-
Decel-
tion Time
ation
eration
2
Time 2
Time 1
A093/A293 F003/F203
A292
Accelera-
Deceleration
tion Time 2
Time 1
A092/A292
F003/F203
Decelera-
tion Time 2
A093/A293
Multi-function Compact Inverter 3G3MX2-V1 User's Manual (I585-E1)
(Example 2) When 1st/2nd 2-step Accelera-
tion/Deceleration Selection (A094/A294) is set to
01 Switch by setting
FW
Acceleration 2
A095/A295
Accelera-
tion 1
Output frequency
Accelera-
Accel-
tion Time 1
eration
Time 2
F002/F202 A092/
A292
Deceleration 2
A096/A296
Deceleration 1
Decel-
Decel-
eration
eration
Time 2
Time 1
F003/F203
A093/
A293

Hide quick links: