Omron MX2 Series User Manual page 59

Mx2 series type v1 multi-function compact inverter
Hide thumbs Also See for MX2 Series:
Table of Contents

Advertisement

Additions/Changes of Monitor Function
The following monitor functions are added or improved to enhance the recognition of operations in your
application.
Parameter
No.
d008
Real Frequency Monitor
d023
Program Counter
(DriveProgramming)
d024
Program Number Monitor
(DriveProgramming)
d025
User Monitor 0
(DriveProgramming)
d026
User Monitor 1
(DriveProgramming)
d027
User Monitor 2
(DriveProgramming)
d030
Current Position Monitor
d062
Frequency Reference Source
Monitor
d063
RUN Command Source Monitor
d130
Analog Voltage Input FV Monitor
d131
Analog Current Input FI Monitor
d133
Pulse Train Input RP Monitor
d153
PID Deviation
d155
PID Output Monitor
Changes of Default Parameter Setting
The default data of the following parameters are changed from the conventional 3G3MX2 Series.
Check if these default values are appropriate for your application.
Parameter
No.
A041
1st Torque Boost Selection
A241
2nd Torque Boost Selection
A047
1st Automatic Torque Boost
Slip Compensation Gain
A247
2nd Automatic Torque
Boost Slip Compensation
Gain
b027
Overcurrent Suppression
Selection
b037
Display Selection
b082
Starting Frequency
b130
Overvoltage Suppression
Function Selection During
Deceleration
C102
Reset Selection
Multi-function Compact Inverter 3G3MX2-V1 User's Manual (I585-E1)
Parameter name
Parameter name
Previous
Previous model
Improved to be displayed always when the Pulse Train Input RP
Selection (P003) is set to 01 (Feedback pulse).
Added as monitor functions for the DriveProgramming function.
Improved to be displayed always when the Pulse Train Input RP
Selection (P003) is set to 01 (Feedback pulse).
Added to monitor the enabled frequency reference.
Added to monitor the enabled RUN command.
Added to monitor the analog voltage input terminal FV.
Added to monitor the analog current input terminal FI.
Added to monitor the pulse train input terminal RP.
Added to monitor the deviation in PID control.
Added to monitor the PID control operation output.
Default data
3G3MX2-V1
model
00
01
00
01
100
0
100
0
00
01
04
00
0.50
1.50
00
01
00
02
1 Overview
Description
Changed to enable the automatic
torque boost function.
Changed to disable the automatic
torque boost slip compensation
function.
Changed to enable the overcurrent
suppression function.
Changed to display all parameters.
Changed to 1.5 Hz.
Changed to enable the overvolt-
age suppression function
Changed to enable only when an
error occurs.
1
1 - 27

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents