Parameter
Function name
No.
GS Input Operation
b145
Selection
Inverter Display on
b150
Operator Connec-
tion
User Monitor Selec-
b160
tion 1
User Monitor Selec-
b161
tion 2
d001/d007 Data
b163
Setting Selection
Initial Screen Auto-
b164
matic Return Func-
tion
Operation Selec-
tion at External
b165
Operator Discon-
nection
b166
(Reserved)
Inverter Mode
b171
Selection
Initialization Exe-
b180
cution
Password A Set-
b190
ting
Password A for
b191
Authentication
Password B Set-
b192
ting
Password B for
b193
Authentication
Motor Electronic
b910
Thermal Selection
Motor Electronic
b911
Thermal Subtraction
*2
Ratio
Motor Electronic
b912
Thermal Subtraction
*2
Time Constant
Motor Electronic
b913
Thermal Integration
*2
Gain
*1. The 3G3MX2-V1 Series Inverter does not provide the high-frequency mode.
*2. These parameters are newly added to the 3G3MX2-V1 Series.
Multi-function Compact Inverter 3G3MX2-V1 User's Manual (I585-E1)
Monitor or data range
00:
No trip (shut off by hardware)
01:
Trip
001 to 060
(Corresponding to d001 to d060)
001 to 030
(Corresponding to d001 to d030)
001 to 030
(Corresponding to d001 to d030)
00:
Disabled
01:
Enabled
00:
Disabled
01:
Enabled
00:
Trip
01:
Trip after deceleration stop
02:
Ignore
03:
Free-run stop
04:
Deceleration stop
Do not change the default 00.
00:
Selection disabled
01:
Induction motor
*1
02:
Do not set.
03:
PM motor
00:
Function disabled
01:
Execute initialization
0000:
Function disabled
0001 to FFFF:
Password
0000 to FFFF
0000:
Function disabled
0001 to FFFF:
Password
0000 to FFFF
00:
Disabled
01:
Enabled (Fixed subtraction
ratio)
02:
Enabled (b911 subtraction
*2
ratio)
03:
Enabled (b912 time parameter
subtraction)
0.10 to 100000.00
(Displays upper 4 digits)
0.10 to 100000.00
(Displays upper 4 digits)
1.0 to 200.0
4 Parameter List
Setting
Changes
Default
Set
during
during
data
data
RUN
RUN
00
Disabled
Enabled
001
Enabled
Enabled
001
Enabled
Enabled
002
Enabled
Enabled
00
Enabled
Enabled
00
Enabled
Enabled
02
Enabled
Enabled
00
00
Disabled
Disabled
00
Disabled
Disabled
0000
Disabled
Disabled
0000
Disabled
Disabled
0000
Disabled
Disabled
0000
Disabled
Disabled
03
Disabled
Enabled
600.00
Disabled
Enabled
120.00
Disabled
Enabled
100.0
Disabled
Enabled
Unit
Page
P. 7-98
P. 7-57
P. 7-13
P. 7-4
P. 7-6
P. 7-56
4
P. 7-56
P. 6-57
P. 5-6
P. 7-57
P. 7-73