4.4.6 Pair Connection– Local Mode
The parameter defines the maintenance status for the pair connection
serial equipment, configure two ICS-210x with Pair Connection mode, it needs to setup one as a Master (Local side) and the
other as a Slave (Remote side).
Pair Connection – Local (Master) – the ICS-210x is locate close to
connects to it via serial interface.
Pair Connection – Remote (Slave) – the ICS-210x is locate close to the remote serial equipment and connects to it
via serial interface.
In effect, this converter will be acting as a TCP server. The screen in Figure 4-48 appears. When changes operation mode,
the user should also change the Serial Port Configuration.
TCP Port Number
Inactive Timeout
Figure 4-47 Pair Connection mode
Figure 4-48 Pair Connection – Local (Master) Configuration screen
The TCP port that ICS-210x uses to listen the connections and that other device
must use to contact ICS-210x. To avoid conflicts with well known TCP ports, the
default is set to "1024".
Use the parameter to set an inactive timeout. The unit drops the connection if
there is no activity on the serial line before the set time expires. To disable the
inactive timeout enter "0".
.
To make a long distance communication between two
the Host Computer or control device and
-49-