Planet ICS-2100 User Manual page 55

Industrial rs-232/rs-422/rs-485 over 100base-fx/10/100base-tx media converter
Hide thumbs Also See for ICS-2100:
Table of Contents

Advertisement

User's Manual of ICS-210x
none, HW
The default value is "none".
 Delimiter
Character The Character 1 and Character 2 allow the use to enter two ASCII
character (in hex format) that delimit the beginning and end of a message. When
a message with both there delimiters is received at the serial port, the data
contained in the serial buffer is paced in an Ethernet packet and sent out the
Ethernet port.
Silent Time: For the defined period of time passed, the serial port stops data
transmission and close the connection to remote host.
Drop Character: If the incoming data contain character 1 or character 2, the
packet will be dropped
The default value is "Disable"
-55-

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ics-2102s15Ics-2105aIcs-2102

Table of Contents