The screen in Figure 4-13 appears. When the changed operation mode, the user should be changed the Serial Port
Configuration.
The page includes the following fields:
 Serial Port Operation Mode
 TCP Port Number
 Inactive Timeout
Figure 4-13 TCP Server mode
Figure 4-14 TCP Server Configuration screen
Choose different mode:
TCP Server
TCP Client
UDP Client
Virtual COM
Telnet Server
Pair Connection - Local(Master)
Pair Connection - Remote(Slave)
The default mode is "Disable".
The TCP port that ICS-210x uses to listen the connections and that other device
must use to contact ICS-210x. To avoid conflicts with well known TCP ports, the
default is set to "1024".
Use the parameter to set an inactive timeout. The unit drops the connection if
there is no activity on the serial line before the set time expires. To disable the
inactive timeout enter "0".