4.4.2 TCP Client Mode

When the ICS-210x be configured to TCP Client mode, it allows Serial device that connected to serial port of ICS-210x to
establish TCP communication actively over Intranet or Internet network between:
Remote Host (Computer) with Serial applications using TCP/IP network socket programs
Other ICS-210x with TCP Server mode
After the data has been transferred, the ICS-210x can disconnect automatically from the Remote Host depends on the TCP
Inactive timeout settings. The parameter defines the maintenance status for listen for the TCP connection
T
he screen in Figure 4-22 appears. When the changed operation mode, the user should be changed the Serial Port
Configuration.
The page includes the following fields:
 Remote Host IP Address
 Remote Host Port Number
 Inactive Timeout
Figure 4-22 TCP Client mode
Figure 4-23 TCP Client Configuration screen
Allow the ICS-210x to connect actively to the remote host whose IP address is
set by this parameter.
The remote host port number that ICS-210x uses to listen to connections and
that other device must use to contact ICS-210x. To avoid conflicts with well
known TCP ports, the default is set to "1024".
Use the parameter to set an inactive timeout. The unit drops the connection if
there is no activity on the serial line before the set time expires. To disable the
inactive timeout enter "0".