User's Manual of OWON Colour Digital Storage Oscilloscope
1. Press the TRIG MENU button to display the trigger menu.
2. Press the F1 menu selection button and choose Video for Type.
3. Press the F2 menu selection button and choose CH1 for Source.
4. Press the F3 menu selection button and choose Field for Sync.
5. Adjust the VOLTS/DIV, VERTICAL POSITION and SEC/DIV knobs to
obtain a proper wave form display (see Fig.71).
Fig. 71 Wave Form Obtained from Video Field Trigger
Video Field Trigger for PDS7062T,PDS7102T
For the trigger in the video field, carry out operations according to the following
steps:
1. Press the TRIG MENU button to display the trigger menu.
2. Press the F1 menu selection button and choose Single for type.
3. Press the F2 menu selection button and choose CH1 for Source.
4. Press the F3 menu selection button and choose Video for Type.
5. Press the F4 menu selection button and choose Field for Sync.
6. Adjust the VOLTS/DIV; VERTICAL POSITION and SEC/DIV knobs to
obtain a proper wave form display (see Fig.72).
81