Figure 2.2 Maximum Load Wire Length For 1 V Line Drop - Xantrex XHR 7.5-130 Operating Manual

Xhr 1000 watt series programmable dc power supply
Table of Contents

Advertisement

Installation
Load Connection
Load Wiring Length for Operation with Sense Lines For applications using
remote sensing, you must limit the voltage drop across each load line.
shows some maximum allowable wire lengths for a given load current and wire size.
We recommend that you use the larger load wiring to ensure a smaller voltage drop
(1 V typical maximum), although the units (except 7.5 V models) will compensate
for up to 5 V drop in each line. See also

Figure 2.2 Maximum Load Wire Length for 1 V Line Drop

Noise and Impedance Effects To minimize noise pickup and radiation, use
shielded pair wiring of shortest possible length for load wires. Connect the shield to
the chassis using the ground screw on the rear panel. Where shielding is impossible
or impractical, simply twisting the wires together will offer some noise immunity.
When using local sense connections, use the largest practical wire size to minimize
the effects of load line impedance on the regulation of the supply.
40
16
12
14
100
90
80
70
60
50
40
30
20
10
"Local and Remote Sensing" on page
WIRE GAUGE (AWG)
8
4
1
10
6
2
LOAD CURRENT (AMPS)
Operating Manual for XHR Series Power Supply
Figure 2.2
2/0
1/0
48.