Scale Error Reporting - Datalogic MAGELLAN 8300 Product Reference Manual

Hide thumbs Also See for MAGELLAN 8300:
Table of Contents

Advertisement

Scale Error Reporting

Remote
Scale Status
Display
Lamp
Flash, pause, 1 blink,
E _1
long pause, repeat
sequence.
Flash, pause, 2
E__2
blinks, long pause,
repeat sequence.
Flash, pause, 3
E__3
blinks, long pause,
repeat sequence.
Flash, pause, 4
E__4
blinks, long pause,
repeat sequence.
Flash, pause, 5
E__5
blinks, long pause,
repeat sequence.
4-6
Scale diagnostics uses the Remote Scale Display and the Zero Status lamp
to communicate specific scale failures. The following chart shows the
Remote Display messages, the Scale Status lamp indication, the problem
that the scale is experiencing and what action should be taken. When
troubleshooting, always remember to check all cable connections first
before proceeding with other problem isolation steps.
Problem
Description
Too much motion at power-
up.
Calibration lost.
Scale communication lost.
Internal scanner/scale prob-
lem.
Scale module failure.
Internal software fault.
Other Scale Reporting
Action Required
Check for stable installation. Change
scale motion filter using the labels
found in
Chapter
6; restart. If prob-
lem persists, scale may require calibra-
tion.
Call technical support personnel. Re-
calibrate; restart; recertify (if required).
Call technical support personnel;
report error.
Call technical support personnel;
report error.
Call technical support personnel;
report error.
®