Step
4.
Configure the startup query
interval.
Configure the startup query
5.
count.
6.
Configure the IGMP general
query interval.
7.
Configure the maximum
response time for IGMP
general queries.
8.
Configure the IGMP
last-member query interval.
9.
Configure the other querier
present interval.
To configure IGMP query and response parameters on an interface:
Step
1.
Enter system view.
2.
Enter interface view.
3.
Configure the IGMP querier's
robustness variable.
4.
Configure the startup query
interval.
5.
Configure the startup query
count.
6.
Configure the IGMP general
query interval.
7.
Configure the maximum
response time for IGMP
general queries.
8.
Configure the IGMP
last-member query interval.
9.
Configure the other querier
present interval.
Command
startup-query-interval interval
startup-query-count value
timer query interval
max-response-time interval
last-member-query-interval
interval
timer other-querier-present
interval
Command
system-view
interface interface-type
interface-number
igmp robust-count robust-value
igmp startup-query-interval
interval
igmp startup-query-count value
igmp timer query interval
igmp max-response-time interval
igmp last-member-query-interval
interval
igmp timer other-querier-present
interval
88
Remarks
By default, the startup query
interval is 1/4 of the "IGMP
general query interval."
By default, the startup query count
is set to the IGMP querier's
robustness variable.
60 seconds by default.
10 seconds by default.
1 second by default.
By default, the other querier
present interval is [ IGMP general
query interval ] × [ IGMP
robustness variable ] + [ maximum
response time for IGMP general
queries ] / 2.
Remarks
N/A
N/A
2 by default.
By default, the startup query
interval is 1/4 of the "IGMP
general query interval."
By default, the startup query count
is set to the IGMP querier's
robustness variable.
60 seconds by default.
10 seconds by default.
1 second by default
By default, the other querier
present interval is [ IGMP general
query interval ] × [ IGMP
robustness variable ] + [ maximum
response time for IGMP general
queries ] / 2.