14.3.5 Digital Operator and Connector Cables

INFO
14
14.3.5 Digital Operator and Connector Cables

PIN1 Power Supply Cable Mounting

J
Connect the P1N1 Power Supply Cable according to the following steps.
1. Turn the cable connector so that the two grooves on the tip are facing left, and then connect the cable.
2. Connect the Inverter using the left connector of the two connectors.
When inserting the connectors, check that the clasp locks with a snap.
Power supply
terminal screws
Make sure the
2 connector
grooves are
facing left.
P1N1 power supply Cable
Fig 14.19
Busbar and Cable Mounting (With Upper Cover Open)
Operations, such as displaying the status of control signals, displaying and setting control constants, and
displaying protection function operations can be performed by mounting an optional JVOP-132 Digital
Operator to the Inverter.
Digital Operator and Extension Cables
J
A Digital Operator Extension Cable (72616-W5301 or 72616-W5303, sold separately) is required to con-
nect a JVOP-132 Digital Operator to the Inverter. Digital Operators and Cables are not supplied with the
Inverter, but must be purchased as needed. Refer to 2.4 Mounting and Dismounting the Digital Operator
and to Chapter 5 Operating the Digital Operator for mounting and operating procedures.
Product
Digital Operator
Extension Cable
(1 m (3.28 ft))
Extension Cable
(3 m (9.84 ft))
Busbars (x2)
Converter
Inverter
Red line
Model
JVOP-132
Use the Digital Operator in combination with an Extension Cable to
set and reference Inverter constants.
Use an Extension Cable to connect the Inverter and the Digital
72616-W5301
Operator. The following are supplied with the Extension Cable:
Cable (1 m or 3 m) (3.28 ft to 9.84 ft) x 1
Cable (1 m or 3 m) (3 28 ft to 9 84 ft) x 1
72616-W5303
Cable clamp
2 types of tapping screws 3 x 10
14 -54
Power supply
terminal screws
Flat cable
Insert into leftmost connector.
Details
x 1
x 2

Hide quick links: