Operation Status Display Mode; Control Constant Display Mode - YASKAWA VS-626M5 Instruction Manual

Vector-controlled inverter drives with power regenerative function for machine tools
Table of Contents

Advertisement

5.3.3 Operation Status Display Mode

To check data in operation status display mode, do as follows. The following shows the example where
U1-09 (sequence input signal status) is to be changed.
Description
S U1-01 is displayed.
S Move blinking cursor to the
data No.
S Select U1-09.
S Display U1-09 data con-
tents.
S Return to operation status
No. display
For explanations of operation status display, refer to Chapter 11 Operating Status Displays.

5.3.4 Control Constant Display Mode

To check data or set/change a constant in control constant display mode, do as follow. The following shows
the example where C1-10 (soft-start time) is to be changed.
Description
S C1-01 is displayed.
S Move blinking cursor to the
data No.
S Select C1-10.
S Display C1-10 data con-
tents.
S Select data line to be
changed.
S Change set value. (1→5)
S Write-in set value.
S Press DATA/ENTER Key
until "End" is displayed.
S Return to control constant
No. display.
Note: When data outside the input range are set, "End" will not appear on the display and all data lines
will continue blinking even when the [DATA/ENTER] is held down. To correct this condition,
depress [DSPL] key returning to the data number display and correct the settings.
Refer to Chapter 10 Control Constants for contents of control constants.
Key
Digital Operator Display
Sequence
RESET
DATA
ENTER
DSPL
Key
Digital Operator Display
Sequence
RESET
DATA
ENTER
RESET
DATA
ENTER
DSPL
5 -7
5.3 Key Operations and Display
Remarks
Depress [>] key once more to return
the blinking cursor.
The display example is the status
when [RDY] and [EMG] signals are
ON.
Remarks
Depress [>] key once more to return
the blinking cursor.
Displayed for 0.5 sec.*
Returns to previous display before
write-in.
5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents