Control Constants
Con-
Name
stant
No.
Internal Speed
Reference Set
Values
C1-41
SPD1 to SPD8
SPD1 to SPD8
to
to
* 2
C1-48
Servo Mode
Speed Refer-
ence Gain
SVGAIN1 and
C1-49
SVGAIN2
SVGAIN2
to
to
* 2
C1-50
C1-51
---
to
C1-53
Speedmeter Sig-
nal Offset Ad-
nal Offset Ad
* 2
* 2
C1-54
C1 54
justment Value
SM
OFS
Load Meter Sig-
nal Offset Ad-
nal Offset Ad
* 2
* 2
C1-55
C1 55
justment Value
LM
OFS
Inverter Capac-
ity Selection
UNITNO
C1-56
Signal Selec-
tions 6
SEL6
C1-57
10
Signal Selec-
tions 7
SEL7
C1-58
C1-59
---
Set values when using internal speed references using digital speed refer-
ences. The correspondence with reference inputs (1CN) are as shown
below, and are given as percentages over the rated speed (C1-26).
Pin 19: SPD1
Pin 19: SPD1
Pin 20: SPD2
Pin 21: SPD3
Pin 22: SPD4
Set value of the analog speed reference read gain in servo mode. (En-
abled when C1-38 bit 3 is ON and C1-40 bit 5 is ON.) Set the ratio of the
number of rotations when the analog speed reference is 10 V over the
rated speed (C1-26).
A l
Analog speed reference 10 V/(S100 x SVGAIN/100) min
Select C1-49 and C1-50 using the DAS signal (C6N-5).
DAS = OFF: C1-49 (SVGAIN1)
DAS = ON: C1-50 (SVGAIN2)
---
Offset adjustment value for speedometer signal. Outputs speedometer
signal after subtracting from SM
signal after subtracting from SM
Offset adjustment value for load meter signal. Outputs speedometer
signal after subtracting from LM
signal after subtracting from LM
Inverter capacity setting. (The setting is already made at factory prior
to shipment.)
200 V class
CIMR
23P7
25P5
−M5
04
Set value
400 V class
CIMR
45P5
−M5
25
Set value
When the setting has changed, turn the control power supply OFF for
3 seconds or longer then ON again.
Control mode signal selections
S Bit 0: Fault record clear selection
* 4
0: Disabled
1: Clears next time control power is turned ON.
(Automatically returns to 0.)
S Bit 4 and 5: Emergency stop fault (AL-21) detection time selection
00: 10 sec
01: 20 sec
10: 40 sec
11: Disabled
Control mode signal selections
S Bit 0: YENET1200 card encoder selection
* 4
0: Motor encoder (2CN)
1: Load shaft encoder (8CN)
When the setting has changed, turn the control power supply OFF then
ON again.
---
Explanation
Pin 23: SPD5
Pin 23: SPD5
Pin 24: SPD6
Pin 25: SPD7
Pin 26: SPD8
d f
10 V/(S100 SVGAIN/100) i
OFS.
OFS.
OFS.
OFS.
27P5
2011
2015 2018 2022
2030
05
06
07
08
09
0A
0B
47P5
4011
4018 4022 4030
4037
4015
27
28
29
2A
2B
2C
26
10-6
Change
Unit
Standard
* 1
No
No
%
%
−1
1
No
No
%
%
.
---
---
5.4
5.4
Yes
Yes
mV
5.4
5.4
Yes
Yes
mV
2037
0C
No
---
4045
2D
No
---
00000000
* 5
No
---
00000000
---
---
Upper
Setting
Limit/
Lower
Limit
100.00
0 00
0.00
0.00
100.00
100.00
100 00
0.00
---
---
200
0
0
−200
200
0
0
−200
---
---
---
---
---
---