Fault Display Mode - YASKAWA VS-626M5 Instruction Manual

Vector-controlled inverter drives with power regenerative function for machine tools
Table of Contents

Advertisement

Operating the Digital Operator

5.3.6 Fault Display Mode

5.3.6 Fault Display Mode
5
IMPORTANT
If a protective function is activated because of a fault, the fault code is displayed. Up to six faults are re-
corded to view the order of a series of faults.
Display Example
Fault Reset
01 occurred
(Overcur-
rent)
Displays the first fault No.
D
Displays the second fault No.
D
Displays the third fault No.
D
Notes on resetting faults
S To reset a fault by the Digital Operator after removing the cause, press [RESET] key in fault display
mode. In other modes, [RESET] key cannot reset the fault.
S Before resetting, turn OFF the run command signals (FWD, REV, ORT) that are externally input.
The reset operation will not be possible if a run command signal is ON.
31 occurred
(Motor Overspeed)
(CPU built-in A/D error)
5 -10
Time
d2 occurred