YASKAWA VS-626M5 Instruction Manual page 50

Vector-controlled inverter drives with power regenerative function for machine tools
Table of Contents

Advertisement

Wiring
3.3.1 Wires and Suitable Crimp Connectors
Model CIMR-
Terminal Symbols
M5
P/¨, N/©
U/T1, V/T2, W/T3
45P5
P/¨, N/©
U/T1, V/T2, W/T3
47P5
P/¨, N/©
U/T1, V/T2, W/T3
4011
4011
3
P/¨, N/©
U/T1, V/T2, W/T3
4015
4015
P/¨, N/©
U/T1, V/T2, W/T3
4018
4018
P/¨, N/©
U/T1, V/T2, W/T3
4022
4022
P/¨, N/©
U/T1, V/T2, W/T3
4030
4030
P/¨, N/©
U/T1, V/T2, W/T3
4037
4037
P/¨, N/©
U/T1, V/T2, W/T3
4045
4045
4011 to
A12/r2, A22/t2 (*2)
4045
* 1. Connect using exclusive-use connection bus bar.
* 2. Provided for open chassis type with a minimum capacity of 11 kW. Not provided for external heatsink cooling type.
Notes: 1. Wire size is selected assuming external suspended wiring of single 3-core cables at
an ambient temperature of 30°C (86°F).
2. If ambient temperature exceeds 30°C (86°F), the allowable current of wire may be lowered.
3. Temperature for each wire indicates the maximum allowable conductor temperature.
Table 3.4
400 V Class Inverter Power Cable Specifications
Tighten-
UL-approved
Terminal
ing
75°C (167°F)
Screw
Torque
Temperature-rated
(N S m)
Copper Wire
[AWG (mm
M6
2.94
M5
2.35
12 (3.3)
M5 × 2
2.35
10 (5.3)
M6
2.94
M5
2.35
12 (3.3)
M5 × 2
2.35
10 (5.3)
M6 × 2
2.94
M6
3.4 to 4.9
10 (5.3)
2.1 to 2.5
M5 × 2,
M5 × 2,
10 (5.3)
10 (5 3)
M6
3.4 to 4.9
M6 × 2
2.94
M6
3.4 to 4.9
8 (8.4)
2.1 to 2.5
M5 × 2,
M5 × 2,
8 (8 4)
8 (8.4)
M6
3.4 to 4.9
M6 × 2
2.94
M6
3.4 to 4.9
8 (8.4)
2.1 to 2.5
M5 × 2,
M5 × 2,
8 (8.4)
8 (8 4)
M6
3.4 to 4.9
M6 × 2
2.94
M6
3.4 to 4.9
6 (13.3)
2.1 to 2.5
M5 × 2,
M5 × 2,
8 (8 4)
8 (8.4)
M6
3.4 to 4.9
M6 × 2
2.94
M8
7.8 to 9.8
4 (21.2)
3.4 to 4.9
M6 × 2,
M6 × 2,
6 (13 3)
6 (13.3)
M6
3.4 to 4.9
M6 × 2
2.94
M8
7.8 to 9.8
3 (26.7)
3.4 to 4.9
M6 × 2,
M6 × 2,
6 (13.3)
6 (13 3)
M6
3.4 to 4.9
M6 × 2
2.94
M8
7.8 to 9.8
1 (42.4)
3.4 to 4.9
M6 × 2,
M6 × 2,
6 (13.3)
6 (13 3)
M6
3.4 to 4.9
M4
1.2 to 2.0
14 (2.1)
3 -10
Wire Sizes
600 V Vinyl-
600 V Cross-
sheath Insulated
linked Polyethy-
Wire (IV, VV)
lene Wire (IC)
60°C (140°F)
90°C (194°F)
2
2
)]
(mm
)
(*1)
2
3.5
(*1)
3.5
3.5
(*1)
5.5
3 5
3.5
(*1)
8
5 5
5.5
(*1)
14
8
8
(*1)
14
8
8
(*1)
22
14
14
(*1)
30
14
14
(*1)
60
14
14
2
600 V Rubber-in-
sulated Cabtyre
Cable (CT)
60°C (140°F)
2
2
(mm
)
(mm
)
2
2
2
3.5
2
3.5
2
3.5
2
5.5
2
2
3 5
3.5
3.5
8
3.5
3 5
5 5
5.5
5.5
14
5 5
5.5
5.5
5 5
8
14
5.5
5 5
5.5
5 5
14
22
8
8
8
8
14
30
8
8
14
14
30
50
8
8
14
14
2
2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents