YASKAWA VS-626M5 Instruction Manual page 298

Vector-controlled inverter drives with power regenerative function for machine tools
Table of Contents

Advertisement

Appendix
15.6.1 Independent Operation for Speed Control Using a Digital Operator
1MCCB
1MC
R
3-phase
S
1
200 VAC*
T
2MCCB
r
1-phase
200 VAC
t
(Grounded to
100 Ω or less.)
15
MCCB: Molded Case Circuit Breaker
MC:
L:
AC reactor
*: 400-V class: 3-phase 400 VAC
Indicated shielded twisted-pair cable
P
3MCCB
P/
N/
L
VS−656MR5
P1
R/L1
N1
S/L2
5CN
T/L3
2MC
A1/r
A2/t
Flat cable
1CN
Not used
Magnetic Contactor
Digital Operator
DRIVE FWD REV
REMOTE
SEQ
REF
DIGITAL OPERATOR
JVOP−132
DRIVE
LOCAL
DSPL
PRGM
REMOTE
DATA
JOG
ENTER
LOCAL
REMOTE
RESET
STOP
RUN
Fig 15.29
Stand-alone Operation Using Digital Operator
Special busbar
N/
P/
P1N1 power
supply cable
P1
VS−626M5
N1
51CN
52CN
Not used
3CN
6CN
19,20,21
EXTCOM0
24VCOM
22,23
0VCOM
24,25
6
RDY
EMG
7
FWD
8
REV
9
TLH
10
11
TLL(INC)
12
SSC(SV)
13
RST
CHW
14
5
DAS
PPI
15
ORT
16
LGR
17
MGR
18
3
SCOM
4
0V
2
SS
33
ZSPD
34
AGR
35
SDET
36
TDET
37
TLE
38
ORG
39
ORE
40
CHWE
COM1
42
43
44
FLT
45
26
FC0
27
FC1
28
FC2
29
FC3
41
FLTL
46
TALM
30 COM2
I/O Card
15 -26
3-phase
1
200 VAC*
U/T1
V/T2
W/T3
(Grounded to
100 Ω or less.)
2CN
+5V
4,5,6
0V
1,2,3
16
PA
17
P
PA
:
PB
18
PB
19
P
:
PLC
14
PLC
15
P
:
8
THSA
9
THSB
P
SS
7
1CN
PAO
13
PAO
14
:
PBO
15
PBO
16
:
PLCO
11
12
PLCO
:
SS 17
EXTCOM 31
24VCOM 32
0VCOM 33
D1
19
D2
20
D3
21
D4
22
D5
23
24
D6
D7 25
D8
26
D9
27
D10
28
D11
29
D12 30
6CN
SM 47
0V 48
LM 50
0V 49
Motor
Cooling fan
Z1
Z2
Z3
U
IM
V
W
1
2
3
4
5
6
PG
7
8
9
TS
11
12
10