YASKAWA VS-626M5 Instruction Manual page 213

Vector-controlled inverter drives with power regenerative function for machine tools
Table of Contents

Advertisement

*3
Model CIMR-M5j
*3
CIMR-MR5j
Ambient Temperature
Heatsink Intake Air Temperature
*6
Storage Temperature
Humidity
Location
Vibration
Protective Structure
* 1. UAASKB-30FZ***E 30/20 kW is 20 minutes (50%ED)/Continuous rated value.
* 2. Rated output power is guaranteed when input voltage is three-phase, 400 V (50/60 Hz), 440 V (50/60 Hz), 460 V (60 Hz).
If input voltage is lower than 400 V, rated output power is not guaranteed.
* 3. A: For stand-alone drive system N: for NC system
* 4. Dimensions of External Heatsink Cooling Type. Refer to 14.1.3 Dimensions for Open Chassis Type.
* 5. An AC reactor is required between Converter and main circuit power supply.
* 6. Temperature during shipping.
45P5
47P5
4011
0°C to 55°C (32°F to 131°F) (not frozen)
0°C to 45°C (32°F to 113°F)
−20°C to 60°C (−4°F to 140°F)
90% or less (non-condensing)
Indoor (protected from corrosive gases and dust), elevation: 1000 m (3280 ft) or less
2
9.8 m/s
(1G) at 10 to less than 20 Hz, up to 2 m / s
(Protected so that parts of the human body cannot reach electrically charged parts from the front)
14 -9
4015
4018
4022
2
(0.2G) at 20 to 50 Hz
IEC IP00
14.1 Drives
4030
14

Hide quick links:

Advertisement

Table of Contents
loading