YASKAWA VS-626M5 Instruction Manual page 192

Vector-controlled inverter drives with power regenerative function for machine tools
Table of Contents

Advertisement

Troubleshooting
12
Table 12.2
Inverter Faults (continued)
Fault No.
Name
Tuneup
incomplete
Orientation command was input be-
(magnetic
fore tuning up (minor fault).
sensor meth-
od orienta-
tion)
Magnetic sen-
Incorrect magnetic sensor signal
sor signal
voltage level during tuning up.
detection er-
ror
Fault of num-
ber of pulses
Number of motor pulses per main
per rotation
axis rotation (4096 ÷ speed gear ra-
(magnetic
tio) exceeded ±6% during tuning
sensor meth-
up.
od orienta-
tion)
Magnetic sen-
Magnetic sensor signal cable was
sor signal dis-
disconnected or connected improp-
connection
erly.
INC signal er-
ror
(Magnetic
INC signal input timing error
sensor meth-
(minor fault)
od orienta-
tion)
YENET1200
Communication error between YE-
communica-
NET1200 card and NC machine.
tion error
Excessive
Position deviation exceeded the al-
position devi-
lowable range.
ation
YENET1200
YENET1200 card memory (PROM)
card ROM er-
error
ror
YENET1200
WDT error between YENET1200
communica-
card and NC machine.
tion WDT er-
ror 1
YENET1200
WDT error between YENET1200
communica-
card and control PCB.
tion WDT er-
ror 2
YENET1200
YENET1200 card detected NMI.
card NMI
YENET1200
YENET1200 card detected division/
card zero di-
overflow error.
vision
Communica-
Answer to communications com-
tions timeout
mand between YENET1200 card
1
and control PCB does not return.
Contents
Corrective Actions
Perform orientation tuneup.
S Check the wiring of magnetic
sensor signal lines.
S Replace the magnetic sensor or
magnetizer.
S Check control constants C1-27,
28, 29.
S Check the wiring of motor en-
coder signal lines.
S Check the wiring of magnetic
sensor signal lines.
S Replace the magnetic sensor or
magnetizer.
S Perform tuneup again.
After carrying out absolute posi-
tioning, change circuit to com-
mand INC signal.
Check the wiring on communica-
tion line.
Check the main axis load.
Replace YENET1200 card.
Check the wiring on communica-
tion line.
Replace the control PCB.
Replace YENET1200 card.
Replace the controller PCB.
12 - 8
Error Code
Ffff
Ffff
Ffff
Ffff
Ffff
---
---
---
---
---
---
---
---

Hide quick links: