Constant Settings; User Constant Functions Table - YASKAWA VS-626M5 Instruction Manual

Vector-controlled inverter drives with power regenerative function for machine tools
Table of Contents

Advertisement

6.4 Constant Settings

This section explains the user constant functions and settings.

6.4.1 User Constant Functions Table

A table of user constant functions is shown below. Change the constant set values depending on the operat-
ing specifications. Refer to 5.3.4 Control Constant Display Mode for setting methods.
Check that the following constant set values match the operating specifications.
D
D
D
Table 6.3
No.
Item
1
Inverter settings
g
2
Machine specification
p
settings
tti
3
Sequence input signal
settings
4
Sequence output signal
q
p
g
settings
tti
5
Speed reference settings
p
g
6
Analog output signal
g
p
g
settings
tti
7
Speed control system
p
y
adjustments
dj t
t
8
Servo mode settings
g
9
Other settings
g
M5A: Stand-alone drive (analog speed reference settings); M5N: NC system (YENET1200 serial communica-
tions)
ON: Constant valid; OFF: Constant not valid (Not used.)
Inverter settings
Machine specification settings
Sequence input signal settings
User Constant Functions
Details
Inverter Capacity Selection
Motor Code Selection
Orientation Control Method Selection
YENET1200 Card Encoder Selection
RUN Mode Selection
Rated Speed
Gear Ratio Settings
Sequence Input Signal Selections
Torque Limit Signal
12-bit Digital Reference Signal Selection
Zero-speed Detection Level (ZSPD)
Speed-agree Signal (AGR)
Speed Detection Signal (SDET)
Torque Detection Signal (TDET)
Soft Start Time Setting
Analog Speed Reference Adjustments
Digital Speed Reference Settings
Speedometer Signal Adjustments
Load Factor Meter Signal Adjustments
Speed Control Gain Adjustments
Motor Flux Lower Limit Level
Torque Reference Filter Time Constant
Analog Speed Reference Gain in Servo Mode
Servo Mode Flux and Base Speed Ratio
Speed System Adjustment in Servo Mode
Zero-speed Braking Time
Excessive Speed Deviation Protection Operation
Adjustments
Load Fault Detection Selection
Fault Record Clear Selection
6 -9
6.4 Constant Settings
Related Constants
C1-56
C1-25
C1-39 bit 0
C1-58 bit 0
C1-37 bits 1 and 0
C1-26
C1-27 to 29
C1-36 bits 1 and 0 (TLL/INC)
C1-36 bit 3 (SSC/SV)
C1-36 bit 4 (PPI/LM10)
C1-37 bit 2 (RDY/EMG2)
C1-40 bit 3 (ORT/NCORT)
C1-24 and C1-38, bit 2
C1-36 bit 7 (Speed/position reference)
C1-19
C1-20 and C1-38 bit 6
C1-21 and C1-22
C1-23 and C1-40 bit 2
C1-10
C1-11, C1-12, and C1-38 bit 5
C1-37 bits 7 and 6, and C1-41 to 48
C1-16 and C1-54
C1-17, C1-55, C1-18, C1-38 bits 1 and 0,
C1-38 bit 7, and C1-40 bit 4
C1-01 to 04
C1-30
C1-09
C1-38 bit 3, C1-40 bit 5, C1-49, and C1-50
C1-31 to 34
C1-05 to 08
C1-35
C1-38 bit 4, and C1-40 bits 1 and 0
C1-40 bit 7
C1-57 bit 0
M5A
M5N
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
6
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON