Sequence Input Signal Circuit (For Stand-Alone Drive) - YASKAWA VS-626M5 Instruction Manual

Vector-controlled inverter drives with power regenerative function for machine tools
Table of Contents

Advertisement

Wiring

3.4.4 Sequence Input Signal Circuit (for Stand-alone Drive)

3.4.4 Sequence Input Signal Circuit (for Stand-alone Drive)
3
Design the input signals in consideration of the following conditions.
The 12-bit digital reference signals into the Inverter's 1CN connectors and the sequence input signals
D
into 6CN connectors can be 0 V, 24 V, or external common signals. The wiring of terminals varies with
the input method as shown below.
To select the external common method, prepare a 24-V (20 to 26 V) power supply for the input signal.
D
The 1CN common and 6CN common terminals are insulated. Therefore, it is possible to used the com-
D
mon terminals individually.
If a relay contact is used, the minimum contact capacity must be 5 mA at 30 V.
D
There will be a signal delay of approximately 5 ms due to the input filter.
D
0 V Common
+24 V Common
External Common
+24 V (or 0 V)
0 V (or +24 V)
Signal Name
Signal Name
EXTCOM
24VCOM
0VCOM
Fig 3.20
Input Method Selections
EXTCOM
24VCOM
0VCOM
3.3kΩ
390Ω
EXTCOM
24VCOM
0VCOM
3.3kΩ
390Ω
EXTCOM
24VCOM
0VCOM
3.3kΩ
390Ω
1CN
31
32
33
3 -32
Pin Number
6CN
19, 20, 21
22, 23
24, 25