E-4 Compaq ProLiant DL380 Generation 2 Server Setup and Installation Guide
Hot-Plug SCSI Hard Drive LED Status Combinations
Activity
Online


On
Off
On
Flashing
Flashing
Flashing
Off
Off
Off
Off
Table E-2
Means
Fault

Off
Do not remove the drive. Removing a drive
during this process causes data loss.
The drive is being accessed and is not configured
as part of an array.
Off
Do not remove the drive. Removing a drive
during this process causes data loss.
The drive is rebuilding or undergoing capacity
expansion.
Flashing
Do not remove the drive. Removing a drive
during this process causes data loss.
The drive is part of an array being selected by the
Array Configuration Utility.
-Or-
The Options ROMPaq is upgrading the drive.
Off
OK to replace the drive online if a predictive
failure alert is received (see the following section
for details) and the drive is attached to an array
controller.
The drive is not configured as part of an array.
-Or-
If this drive is part of an array, then a powered-on
controller is not accessing the drive.
-Or-
The drive is configured as an online spare.
On
OK to replace the drive online.
The drive has failed and has been placed off-line.