D-4 Compaq ProLiant DL380 Generation 2 Server Setup and Installation Guide
G
"Automatic Server Recovery-2"
G
"System Short Circuit" for other reasons for repeatedly rebooting
7. Restart the server.
IMPORTANT: If the server does not restart, proceed to the following section, "Diagnostic
Steps."
8. Check the server for the following normal power-up sequence to verify
that your system meets the minimal hardware requirements and is
powered up during normal operations:
a. The front panel power LED turns from standby (amber) to on (solid
green).
b. The fans start up.
9. Check the monitor, if you have a monitor installed, for the following
messages that verify your system meets the minimal hardware
requirements and is powered up during normal operations:
G
Compaq ProLiant logo
G
Memory test
G
ROM information
G
Copyright information
G
Processor initialization
G
PXE initialization
G
Array controller initialization
G
SCSI devices
10. The operating system loads to complete the boot process.
If the server completes POST and attempts to load the operating system, go to
the "Problems After Initial Boot" section in this appendix.