D-8 Compaq ProLiant DL380 Generation 2 Server Setup and Installation Guide
Answer
No
Yes
Note: For LED locations and functions, see Appendix E, "LED Indicators and Switches." For cabling
configurations, see Chapter 6, "Server Cabling."
Answer
No, it is
amber
No, it is
red
Yes
Note: For LED locations and functions, see Appendix E, "LED Indicators and Switches." For cabling
configurations, see Chapter 6, "Server Cabling."
Is the System Power LED Green?
Possible Reasons
Power On/Standby button has not been pressed
firmly.
A power supply problem exists. The power
supply may not be inserted properly, it may
have a damaged connector, or it may have
failed.
The system may have experienced a short.
The power converter module, system board,
SCSI backplane, and/or power button/LED board
may need to be replaced.
If the system power LED is green, see Table D-4.
Is the External Health LED Green?
Possible Reasons
One power supply has failed; therefore, power
supply redundancy is lost.
All installed power supplies have failed.
The system may have experienced a short.
If the external health LED is green, see Table D-5.
Table D-3
Possible Solutions
Firmly press the Power On/Standby
button.
Ensure that the power supply is
undamaged, and the power supply is
fully seated.
Check for bent pins on connectors and
components.
Check for unseated expansion boards.
If these solutions do not solve the
problem, contact your Compaq
authorized service provider for
assistance.
Table D-4
Possible Solutions
Identify the failed power supply (no green
LED): ensure that the power supply is
undamaged and the power supply is fully
seated.
Contact your Compaq authorized service
provider for replacement parts and
service.
Contact your Compaq authorized service
provider for replacement parts and
service.