Answer
Possible Reasons
No, it is
A processor is in pre-failure condition.
amber
A DIMM is in pre-failure condition.
One memory bank is valid, but another bank is
missing a DIMM.
One memory bank is valid, but another bank
has mismatched DIMMs installed.
One memory bank is valid, but another bank
has an unsupported DIMM type installed.
A memory bank has failed and the online spare
memory feature has copied information to the
redundant bank.
A redundant fan has failed.
No, it is
A processor has failed.
red
Processor 1 is not installed.
A processor is an unsupported type.
Processors are mismatched (speed and/or type).
A PPM has failed.
A PPM is not installed.
A DIMM has experienced a multibit error.
No valid memory in the system. Populated
banks have mismatched DIMMs.
No valid memory in the system. Populated
banks have missing DIMMs.
No valid memory in the system. Populated
banks have unsupported DIMM types.
A primary fan has failed.
The power converter module has failed.
PCI riser or Smart Array 5i Controller is
unseated.
An overtemperature condition has occurred.
Table D-5
Is the Internal Health LED Green?
Troubleshooting D-9
Possible Solutions
Use amber failure LEDs to identify:
I
Missing components
I
Degraded components
I
Failed components
I
Improperly installed components
Contact your Compaq authorized service
provider for replacement parts and
service.
Use amber failure LEDs to identify:
I
Missing components
I
Failed components
I
Improperly installed components
I
Overtemperature event
Contact your Compaq authorized service
provider for replacement parts and
service.