8-6 Compaq ProLiant DL380 Generation 2 Server Setup and Installation Guide
PCI Hot Plug LED Status Combinations
LED
Power Status
On
Green
Off
Amber
On
Green
On
Amber
Flashing
Green
On or off
Amber
Table 8-3
OK to Open
Slot Status
No
Power is currently applied to the slot. Do NOT
open the slot release lever. The slot is
functioning normally.
No
Power is currently applied to this slot, but the
slot needs ATTENTION for a possible problem
with the slot, board, or driver. Do NOT open
the slot release lever. Examine the logs and
Compaq Insight Manager XE. If the expansion
board is faulty, follow these steps:
1.
Through the PCI Hot Plug application,
turn off the power to the slot (the green
LED turns off).
2.
Open the slot release lever (the amber
LED turns off).
3.
Remove or replace the expansion board.
4.
Connect the cables to the expansion
board.
5.
Close the slot release lever.
6.
Return power to the slot through the PCI
Hot Plug application or by pressing the
PCI Hot Plug button (the green LED turns
on).
No
Power to this slot is being turned off or on,
which may take several minutes. DO NOT open
the slot release lever until the green LED is
completely off. Press the PCI Hot Plug button to
cancel the operation.
continued