HP 53131A/132A 225 MHz Programming Manual page 58

225 mhz universal counter
Table of Contents

Advertisement

Keyword/Syntax
Parameter Form
[:SENSe] (Cont.)
:FUNCtion
<sensor_function> (See below)
[:ON]
:PHASe
:ARM
[:STARt]
:SLOPe
POSitive | NEGative
IMMediate | EXTernal
:SOURce
:ROSCillator
:EXTernal
ON | OFF | ONCE
:CHECk
:FREQuency?
Chapter 2 Command Summary
HP 53131A/132A Command Summary
Table 2-2. HP 53131A/132A SCPI Command Summary (Continued)
" [:][XNONe:]DCYCle [1] "
" [:][XNONe:]PDUTycycle [1] "
" [:][XNONe:]FALL:TIME [1] "
" [:][XNONe:]FTIMe [1] "
" [:][XNONe:]FREQuency [1 | 2 | 3] "
" [:][XNONe:]FREQuency:RATio
[1,2 | 1,3 | 2,1 | 3,1] "
" [:][XNONe:]NWIDth [1] "
" [:][XNONe:]PERiod [1 | 2 | 3] "
" [:][XNONe:]PHASe [1,2] "
" [:][XNONe:]PWIDth [1] "
" [:][XNONe:]RISE:TIME [1] "
" [:][XNONe:]RTIMe [1] "
" [:][XNONe:]TINTerval [1,2] "
" [:][XNONe:]TOTalize [1] "
" [:][XNONe:]VOLTage:MAXimum [1 | 2] "
" [:][XNONe:]VOLTage:MINimum [1 | 2] "
" [:]{XNONe:]VOLTage:PTPeak [1 | 2]
______________________________
1
For HP 53131A firmware revision s below 3335, only Ratio 1 to 2 and Ratio 1 to 3 were offered.
2-34
Std/
Comments
New
Std
Subtree. Selects the <sensor function> to
be sensed by the instrument.
Std
Sets the <sensor function> to be sensed by
the instrument.
New
(Positive) duty cycle on channel 1.
New
(Positive) duty cycle on channel 1.
New
Fall Time on channel 1.
New
Fall Time on channel 1.
Std
Frequency on channel 1, 2, or 3.
1 Frequency Ratio 1 to 2, 1 to 3, 2 to 1, or 3
Std
to 1.
New
Negative Pulse Width on channel 1.
Std
Period on channel 1, 2, or 3.
Std
Phase of channel 1 relative to channel 2.
New
Positive Pulse Width on channel 1.
New
Rise Time on channel 1.
New
Rise Time on channel 1.
New
Time Interval channel 1 to channel 2.
Std
Totalize on channel 1.
Std
Voltage Maximum on channel 1 or 2.
New
Voltage Minimum on channel 1 or 2.
New
Voltage Peak to Peak on Channel 1 or 2.
New
Subtree. Controls the phase measuring
capabilities of the instrument.
New
Subtree.
New
Subtree. Synchronizes Phase start arm with
events.
New
Sets the slope of the external start arm
signal used in external arming phase
measurements. Only applies when
[:SENS]:PHAS:ARM[:STAR]:SOUR EXT is
selected.
New
Sets the start arm for phase
Std
measurements.
Std
Subtree. Controls the Reference
New
OSCillator.
Subtree.
Std
Set the enable for checking the validity and
presence of the external reference.
Query only. Returns the frequency value of
the external reference oscillator.
Programming Guide