Printer Commands
^A
^D
COMMAND
119
Display Memory Allocation.
This command shows how all of the RAM and FLASH memory is being used.
Example display from the ^D119 command:
Ram Based Fonts/Graphics(TCI=8) - [file number(CGN), size, type]
[2,4625, Font set]
Ram Based Formats - [file number, size]
[2,176]
Total Ram Memory Available - 258335 ←There are 258,335 bytes of RAM available.
Flash Based Fonts/Graphics(TCI=7) - [file number(CGN), banks used, type]
[1,1, Graphic] ←Slot #1 of FONT flash has a GRAPHIC that takes up 1 bank (64Kbyte)
Font/Graphic Flash Memory Banks Available – 119 ←There are 119 banks of 64KB open.
Flash Based Formats - [file number, size]
[1,176] ←Slot #1 of FORMAT flash has a FORMAT file that is 176 bytes.
Format Flash Memory Available - 65359 ←There are 65,359bytes of FORMAT flash open.
Label Memory - [size, available]
[43231,41618] ←The difference is the amount of memory to process current format.
NOTES: RAM GRAPHICS can extend beyond the starting slot # into sequential ones.
RAM formats are numbered #1 to #128 (RAM FONTS are limited to 64K in size.)
^A
^D
COMMAND
122
Display Available FONT/GRAPHICS FLASH Memory.
This command is used to display the amount of FONT/GRAPHICS FLASH
memory available in bytes in the form >xxxxxxx< where xxxxxxx is the number
of available bytes.
XX
130
Save a FORMAT to FLASH. (non-volatile memory)
The ^Axx selects the memory slot (1- 128) into which the format is to be
saved. A format file must be terminated by an ESC (HEX 1B) or "[" (left
bracket) character to save the format.
How to Save a Label FORMAT to FLASH:
1)Create the FORMAT file with ^Axx^D130 at the top to tell the printer to store into FLASH
Slot #xx,
2)Send the file to the printer using a standard communications program.
Sample format saved to RAM slot #1:
5-40
← Slot #2 in RAM has a FONT that is 4,625 bytes.
Slot #2 in FORMAT RAM has a FORMAT that is 176 bytes.
^A1^D130
^D57
1,1280,900,20,40,7,0,1,405,0,0
1,640,650,12,1,5,0,4,2,2,,,,,0
^D56
^D2
Saved Format
^D3
^[
324M/424M Operator's Manual - 880026-1001