^A
^D
Command
XX
102
Full Cut Interval: Instructs the printer when to issue a Full Cut. The default
value is 1. If it is set to a value of "1" the printer will full cut whenever the
copies count has been reached or after each format if a copies count has not
been specified. If this command is set higher than "1" (maximum of 65536),
the printer will full cut when that quantity has been reached. This command
will not operate if the Cutter Control (^D99) command is set to partial cut.
XX
103
Partial Cut Interval: This command instructs the printer when to issue a
Partial Cut. A partial cut requires the use of a Cutter that is capable of Partial
cuts. Partial Cut is when a thin piece of the media, in the center, holds the
media together and the printer waits until the media is removed before printing
the next label. The default Partial Cut Interval is set to 1. The printer will issue
a partial cut, if set to a 1, whenever the copies count is reached. If set to a
value greater than 1, the printer will partial cut when that quantity has been
reached. This command only functions when the Cutter Control (^D99)
command is set to allow partial cuts.
XX
104
Save ASCII Fonts to RAM:
The ^Axx specifies which memory file # (CGN #) the FONT will use (1-255).
This command should be used with an ASCII-HEX file that contains only
printable characters less than 80 HEX. These FONTS are "extended non-
compressed", meaning that they can be greater than 64KB.
This command supports fonts greater than 64KB.
XX
105
Delete Graphics from RAM
^A0 deletes ALL graphics from RAM.
^Ax deletes the graphics in slot #x.
XX
106
Save ASCII Graphics to RAM.
This command is intended for legacy support only. Microcom Corporation
recommends using the ^D107 command instead of the ^D106.
xxyy 107
Save Compressed GRAPHICS to RAM.
The special ^Axxyy^D107 code is put at the beginning of the GRAPHIC
download file by the bit map converter program. The ^Axxyy tells the printer
the overall size of the file according to this format:
xx = the number of additional 64KB sectors in the GRAPHIC file set
yy = CGN # (1-255)
XX
108
Serial Communication Port Command (Non-volatile).
This command tells the printer how to determine the HOT comm. port on the
next power-ON. This command is stored in FLASH and only takes effect on
the next power cycle.
XX
109
Serial Communication Port Command (Volatile).
This command tells the printer to immediately switch to a specific comm. port.
This command is NOT stored in FLASH, so it will be lost when the printer
powers OFF.