^A
^D
Command
80
Clears Command 86, 88, and 89
81
Disable Serial Number Function: This command disables the serial number
function for either single or multiple serial numbers.
XX
84
Load Text String Number to Increment/Decrement: Instructs the printer
which text string to increment/decrement. Only used in conjunction with single
serial numbers.
XX
85
Load Increment/Decrement Step Value: The ^Axx specifies the value that
the serial number will be incremented or decremented.
X
86
Single Serial Number Status:
0
Disable Increment/Decrement
1
Enable Increment. The serial number will be increased by the ^D85 value.
2
Enable Decrement. The serial number will be decreased by the ^D85 value.
XX
87
Load Field Number to Clear Increment/Decrement Status: Clears the
status of one or more serial numbers.
XX
88
Load Field Number to Increment by 1: The ^Axx specifies which field to
increment when using the multiple serial number function.
XX
89
Load Field Number to Decrement by 1: The ^Axx specifies which field to
decrement when using the multiple serial number function.
XX
90
Reflective Detection Sensitivity: The ^Axx value sets the point (0-255) at
which the printer detects a blackline registration mark using the reflective
sensor. The printer's threshold default is a value of 100 for the reflective
sensor. If this value is not set correctly the printer may false sense a
registration mark or report an invalid >LOW STOCK< error.
XX
91
Gap Detection Sensitivity: The proper value can generally be obtained by
using the ^D39 auto-size commands. The ^Axx value sets the point (0-255) at
which the printer detects a gap, blow-hole and/or blackline. When the printer
is powered-up or reset, this command defaults to a value of 30 if using the
transmissive sensor and 100 if using the reflective sensor. Although the
default value should work properly with most media types, it is a good idea to
place this command at the beginning of all format files in order to guarantee
that the printer will properly detect your media's registration mark. If this value
is not set correctly the printer may false sense a GAP or report an invalid
>LOW STOCK< error.
XX
92
Set Starting Slice Number: This command adjusts the number of slices (dot
rows) generated before the printer starts moving the label stock.
X
93
Load Control Code Recognition Status:
0
1
324M/424M Operator's Manual - 880026-1001
Enable control code recognition
Disable control code recognition
13-9
Need help?
Do you have a question about the 324M and is the answer not in the manual?
Questions and answers